Manual p. 1–4

A 100 % domestically produced isolated DC/DC converter in a five-sided metal shell with dual-in-line through-hole pins — 3 W from a 4.5–9 V input, 5 W from 9–40 V or 16–40 V, single or dual output, in a 12.7 × 12.7 × 10.8 mm package.

Input
4.5–9 / 9–40 / 16–40 VDC
Output power
3 W · 5 W
Efficiency
76–86 % typ.
Package
12.7 × 12.7 × 10.8 mm
Request a quoteDatasheet (PDF)
Semi-custom part numbers can be assigned to your requirement — contact engineering for tightened parameters or extended temperature grades.

Product Features

Isolated output
High efficiency
Low ripple
Five-sided metal package
Fixed switching frequency
Small size
Input under-voltage protection
Output over-current protection
Output short-circuit protection
Enable (ON/OFF) control
No minimum-load requirement
100 % localised

Application Areas

Aerospace
Vehicle systems
Airborne equipment
Electrical specifications
Input voltage range4.5–9 VDC, 5.0 typ. (5 series) · 9–40 VDC, 28 typ. (18 series) · 16–40 VDC, 28 typ. (28 series)
Input under-voltage protection3.75–4.5 VDC (5 series) · 7–9 VDC (18 series) · 13–16 VDC (28 series), half load
Input surge voltage50 VDC max. (18/28 series, 100 ms, full load)
Output voltage accuracy−1.0 / 0.5 typ. / +1.0 %Vo, full load
Line regulation±1.0 %Vo (full temperature, full input range, full load)
Load regulation±2.0 %Vo (full temperature, full input range, full load range, dual outputs balanced)
Start-up time4 ms typ. (full load)
Transient overshoot / recovery±5.0 %Vo / 500 µs max. (25–50–25 %, 50–75–50 %, di/dt = 0.1 A/µs)
Output over-current protection≥110 %Io, hiccup mode, self-recovering
Output short-circuit protectionhiccup mode, self-recovering
Switching frequency300 kHz typ.
Enable (positive logic)−0.3–0.7 VDC: output off · 3.5–12 VDC or open: output on
Insulation resistance≥100 MΩ at 500 VDC (input, output, case)
Isolation voltage1000 V input-to-output, 1 min, ramp 500 V/s, leakage ≤3.5 mA, no arcing or breakdown
Part Numbering Rule
ERM – 28 – S – 05 – M – 5 – P – S
ERMStandard power module, 12.7 × 12.7 × 10.8 mm
28Input voltage: 5 = 4.5–9 V, 18 = 9–40 V, 28 = 16–40 V
SOutputs: S = single, D = dual
05Output voltage: 3V3 = 3.3 V, 05 = 5 V, 06 = 6 V … 28 = 28 V
MTemperature grade: M = enterprise-military, −55 to +105 °C · T = industrial, −40 to +85 °C
5Output power: 3 = 3 W, 5 = 5 W
PLogic: P = positive
SMounting: S = standard
Product Model List

33 catalogued part numbers

Check availability
ERM Series — catalogued part numbers and key parameters
Part numberV-in (V)V-out (V)I-out (A)η typ. (%)Cap. load (µF)Ripple typ. (mVpp)ZZKK grade
YSERM05S3V3M3PS4.5–93.30.917647030C
YSERM05S05M3PS4.5–950.68222030C
YSERM05S06M3PS4.5–960.58222020C
YSERM05S09M3PS4.5–990.338315030C
YSERM05S12M3PS4.5–9120.258415030C
YSERM05S15M3PS4.5–9150.28510030C
YSERM05S24M3PS4.5–9240.138410040C
YSERM05S28M3PS4.5–9280.11844740C
YSERM05D05M3PS4.5–9±50.38015030C
YSERM05D12M3PS4.5–9±120.13844730C
YSERM05D15M3PS4.5–9±150.1844730C
YSERM18S3V3M5PS9–403.31.57833040C
YSERM18S05M5PS9–40518233040C
YSERM18S06M5PS9–4060.838433040C
YSERM18S09M5PS9–4090.568422030C
YSERM18S12M5PS9–40120.428622030C
YSERM18S15M5PS9–40150.338522030C
YSERM18S24M5PS9–40240.218610040C
YSERM18S28M5PS9–40280.188410040C
YSERM18D05M5PS9–40±50.58022040C
YSERM18D12M5PS9–40±120.218310040C
YSERM18D15M5PS9–40±150.178310040C
YSERM28S3V3M5PS16–403.31.57847040C
YSERM28S05M5PS16–40518247040C
YSERM28S06M5PS16–4060.838447040C
YSERM28S09M5PS16–4090.568522030C
YSERM28S12M5PS16–40120.428622030C
YSERM28S15M5PS16–40150.338622030C
YSERM28S24M5PS16–40240.218610040C
YSERM28S28M5PS16–40280.188510040C
YSERM28D05M5PS16–40±50.58022040C
YSERM28D12M5PS16–40±120.218310040C
YSERM28D15M5PS16–40±150.178310040C

For the complete selection, please contact engineering — more variants, packages and grades are available than listed here.

Contact engineering

Performance figures are typical values; the detailed product specification or datasheet supplied by Yueyang governs. Only typical part numbers are listed — models can be customised to customer requirements.